Reagents
switchSENSE® Solutions for Research & Development
COUPLING KIT
Selection Wizard
Demo
& QC Kits
Buffers &
Solutions
Coupling
Kits
Coupling Kits
To link a ligand onto the complementary DNA strand, we offer a range of Coupling Kits. For further information about the binding theory and chip functionalization please check our Application Library. In case you have any questions, please contact info@dynamic-biosensors.com.
Email order@dynamic-biosensors.com for ordering and product information.
Order No. | Kit | DNA length | Product Description |
---|---|---|---|
CK-NH2-1-B48 | Amine coupling 1 | 48 | for proteins (>5 kDa); cNL-B48 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-1-A48 | Amine coupling 1 | 48 | for double color applications for proteins (>5 kDa); cNL-A48 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-1-B96 | Amine coupling 1 | 96 | for proteins (>5 kDa); cNL-B96 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-1-A96 | Amine coupling 1 | 96 | for double color applications for proteins (>5 kDa); cNL-A96 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-2-B48 | Amine coupling 2 | 48 | for proteins (>5 kDa); cNL-B48 and NHS modifier, sufficient for 5 different conjugations (spin column purification) |
CK-NH2-2-B96 | Amine coupling 2 | 96 | for proteins (>5 kDa); cNL-B96 and NHS modifier, sufficient for 5 different conjugations (spin column purification) |
PF-NH2-1 | proFIRE® Amine Coupling Kit 1 | n/a | for proteins (>5 kDa) sufficient for 5 conjugations |
PF-NH2-2 | proFIRE® Amine Coupling Kit 2 | 48 | for His-tagged proteins (>5 kDa) sufficient for 3 conjugations |
CK-NH2-3-B48 | Amine coupling 3 | 48 | for small molecules and peptides (< 5 kDa); cNL-B48 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-5-B96 | Amine coupling 5 | 96 | for bi-functional analytes two antigens (distance 7 nm) - one nanolever NHS modifier, sufficient for 5 different conjugations |
CK-NH2-6-B96 | Amine coupling 6 | 96 | for bi-functional analytes two antigens (distance 14 nm) - one nanolever NHS modifier, sufficient for 5 different conjugations |
CK-NH2-7-B48 | Amine coupling 7 | 48 | for proteins (> 5 kDa) with a low pI (pI < 6) cNL-B48 and NHS modifier, sufficient for 5 different conjugations |
CK-NH2-7-B96 | Amine coupling 7 | 96 | for proteins (> 5 kDa) with a low pI (pI < 6) cNL-B96 and NHS modifier, sufficient for 5 different conjugations |
CK-SH-1-B48 | Thiol coupling 1 | 48 | for proteins (>5 kDa) cNL-B48 and Maleimide modifier, sufficient for 5 different conjugations |
CK-SH-1-B96 | Thiol coupling 1 | 96 | for proteins (>5 kDa) cNL-B96 and Maleimide modifier, sufficient for 5 different conjugations |
CK-SH-2-B48 | Thiol coupling 2 | 48 | for proteins (>5 kDa) cNL-B48 and Maleimide modifier, sufficient for 5 different conjugations (spin column purification) |
CK-SH-2-B96 | Thiol coupling 2 | 96 | for proteins (>5 kDa) cNL-B96 and Maleimide modifier, sufficient for 5 different conjugations (spin column purification) |
CK-SH-3-B48 | Thiol coupling 3 | 48 | for small molecules and peptides (< 5 kDa) cNL-B48 and Maleimide modifier, sufficient for 5 different conjugations |
PF-SH-1 | proFIRE® Thiol Coupling Kit 1 | n/a | for proteins (>5 kDa) sufficient for 5 conjugations |
CK-CLK-1-B48 | Click coupling | 48 | cNL-B48 with DBCO modification, sufficient for 5 different reactions |
CK-DG-1-B48 | Digoxigenin | 48 | cNL-B48 modified with digoxigenin, sufficient for 20 regenerations |
CK-DG-1-B96 | Digoxigenin | 96 | cNL-B96 modified with digoxigenin, sufficient for 20 regenerations |
CK-TN-1-B48 | Tris-NTA | 48 | cNL-B48 modified with Tris-NTA, sufficient for 20 regenerations |
CK-TN-1-B96 | Tris-NTA | 96 | cNL-B96 modified with Tris-NTA, sufficient for 20 regenerations |
CK-SA-1-B48 | Streptavidin | 48 | cNL-B48 modified with Streptavidin, sufficient for 20 regenerations |
CK-SA-1-B96 | Streptavidin | 96 | cNL-B96 modified with Streptavidin, sufficient for 20 regenerations |
CK-SXT-1-B96 | Strep-Tactin® XT | 96 | cNL-B96 modified with Strep-Tactin® XT*, sufficient for 20 regenerations |
CK-CS1-B96 | CaptureSelect™ Anti-LC-kappa (Murine) Conjugate | 96 | cNL-B96 modified with CaptureSelect™** Anti-LC-kappa (Murine), sufficient for 20 regenerations |
CK-CS2-B96 | CaptureSelect™ Anti-IgG-Fc Rabbit Conjugate | 96 | cNL-B96 modified with CaptureSelect™** Anti-IgG-Fc Rabbit, sufficient for 20 regenerations |
CK-FC-1-B48 | Fc binding Protein A | 48 | cNL-B48 modified with Protein A, sufficient for 20 regenerations |
CK-FC-1-B96 | Fc binding Protein A | 96 | cNL-B96 modified with Protein A, sufficient for 20 regenerations |
CK-FC-2-B48 | Fc binding Protein G | 48 | cNL-B48 modified with Protein G, sufficient for 20 regenerations |
CK-FC-2-B96 | Fc binding Protein G | 96 | cNL-B96 modified with Protein G, sufficient for 20 regenerations |
CK-GFP-1-B48 | GFP binding protein | 48 | cNL-B48 modified with GFP binding protein***, sufficient for 20 regenerations |
CK-GFP-1-B96 | GFP binding protein | 96 | cNL-B96 modified with GFP binding protein***, sufficient for 20 regenerations |
CK-GST-1-B48 | GST binding protein | 48 | cNL-B48 modified with GST binding protein***, sufficient for 20 regenerations |
CK-GST-1-B96 | GST binding protein | 96 | cNL-B96 modified with GST binding protein***, sufficient for 20 regenerations |
RK-PA-1 | Reducing Agent 1 | for Proteins and Antibodies Chemical Reduction of disulfide bonds with TCEP |
*Strep-Tactin® XT is a product of IBA GmbH |
|
**Capture SelectTM is a product of Thermo Fisher Scientific |
|
***GFP / GST binding protein is a product of ChromoTek GmbH |
QUESTIONS?
Contact us – we are happy to help.
Demo & QC Kits
Demo & QC Kits are ideal for teaching or revision. Supplied with a detailed user’s manual and reagents they will guide users through a full experiment.
In general we recommend an annual service visit, which includes a complete documented re-qualification of the instrument according to QC standards.
Email order@dynamic-biosensors.com for ordering and product information.
Order No. | Kit | Application |
---|---|---|
DK-DC-1-B48 | Demo kit protein – small molecule – Dual color (kon | koff) | Association and dissociation of two antibody fabs in parallel. |
DK-BP-1-B48 | Demo kit protein – small molecule (kon | DH | koff) | Association, size and dissociation of an anti-Biotin Fab fragment, needs Multi-purpose Biochips with NL-B48. |
DK-QC-A48-1 | QC DRX kit DNA hypridization kinetics using a 7mer oligo | This kit contains all reagents and chips for checking functionality and performance of DRX and DRX2 instruments. |
Would you like to get more INFO
or arrange a DEMO?
Contact us, we will get in touch with you shortly!
Buffers & Solutions
We offer a range of standard buffers and solutions optimized for switchSENSE® experiments.
The platform is highly tolerant to a wide range of buffers. Download our compatibility chart at our Application Library.
Email order@dynamic-biosensors.com for ordering and product information.
Order No. | Buffer / Solution | Product description |
---|---|---|
BU-TE-40-10 | 10x Buffer TE40 pH 7.4 | 50 mL of: 100 mM Tris-HCl, 400 mM NaCl, 0.5 % Tween20, 0.5 mM EDTA,0.5 mM EGTA; Yields 0.5 L of: 10 mM Tris-HCl, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA,50 μM EGTA |
BU-PE-40-10 | 10x Buffer PE40 pH 7.4 | 50 mL of: 100 mM Na2HPO4/NaH2PO4, 400 mM NaCl, 0.5 % Tween20, 0.5 mM EDTA, 0.5 mM EGTA; Yields 0.5 L of: 10 mM Na2HPO4/NaH2PO4, 40 mM NaCl, 0.05 % Tween20, 50 µM EDTA, 50 µM EGTA |
BU-HE-40-10 | 10x Buffer HE40 pH 7.4 | 50 mL of: 100 mM Hepes, 400 mM NaCl, 0.5 % Tween20, 0.5 mM EDTA, 0.5 mM EGTA; Yields 0.5 L of: 10 mM Hepes, 40 mM NaCl, 0.05 % Tween20, 50 µM EDTA, 50 µM EGTA |
BU-TE-140-10 | 10x Buffer TE140 pH 7.4 | 50 mL of: 100 mM Tris-HCl, 1.4 M NaCl, 0.5 % Tween20, 0.5 mM EDTA, 0.5 mM EGTA; Yields 0.5 L of: 10 mM Tris-HCl, 140 mM NaCl, 0.05 % Tween20, 50 µM EDTA, 50 µM EGTA |
BU-PE-140-10 | 10x Buffer PE140 pH 7.4 | 50 mL of: 100 mM Na2HPO4/NaH2PO4, 1.4 M NaCl, 0.5 % Tween20, 0.5 mM EDTA, 0.5 mM EGTA; Yields 0.5 L of: 10 mM Na2HPO4/NaH2PO4, 140 mM NaCl, 0.05 % Tween20, 50 µM EDTA, 50 µM EGTA |
BU-HE-140-10 | 10x Buffer HE140 pH 7.4 | 50 mL of: 100 mM Hepes, 1.4 M NaCl, 0.5 % Tween20, 0.5 mM EDTA. 0.5 mM EGTA; Yields 0.5 L of: 10 mM Hepes, 140 mM NaCl, 0.05 % Tween20, 50 µM EDTA, 50 µM EGTA |
BU-C-150-1 | 1x Buffer C pH 8.0 | 50 mL of: 50 mM Na2HPO4/NaH2PO4, 150 mM NaCl |
BU-P-150-10 | 10x Buffer A pH 7.2 | 50 mL of: 500 mM Na2HPO4/NaH2PO4, 1.5 M NaCl; Yields 0.5 L of: 50 mM NaH2PO4/NaH2PO4, 150 mM NaCl |
BU-P-1000-5 | 5x Buffer B pH 7.2 | 50 mL of: 250 mM Na2HPO4/NaH2PO4, 5 M NaCl; Yields 0.25 L of: 50 mM NaH2PO4/NaH2PO4, 1 M NaCl |
BU-P-5-10 | 10x P5 Buffer pH 7.3 | 50 mL of: 50 mM NaH2PO4/Na2HPO4 pH 7.3; Yields 0.5 L of: 5 mM NaH2PO4/Na2HPO4 pH 7.3 |
BU-M-150-1 | 1x Buffer MES pH 6.5 | 12 mL of: 50 mM 2-(N-Morpholino)ethanesulfonic acid, 150 mM NaCl) |
CNL-A48-500 | cNL-A48 solution | solution of complementary DNA lever for sequence A48, cNL-A48 500 μL / 1 μM |
CNL-A96-500 | cNL-A96 solution | solution of complementary DNA lever for sequence A96, cNL-A96 500 μL / 1 μM |
CNL-B48-500 | cNL-B48 solution | solution of complementary DNA lever for sequence B48, cNL-B48 500 μL / 1 μM |
CNL-B96-500 | cNL-B96 solution | solution of complementary DNA lever for sequence B96, cNL-B96 500 μL / 1 μM |
CNL-DP36-500 | Solution of dideoxy-P36 DNA | solution of Dideoxy-P36 DNA for usage with ENZ-80-1-R1-X or ENZ-80-1-Y1-X, DDO-P36 500 μL / 1 μM |
CNL-P36T80-500 | P36T80 solution | solution of P36T80 DNA strand for usage with ENZ-80-1-R1-X or ENZ-80-1-Y1-X, P36T80 500 μL / 1 μM |
CNL-P48T80-500 | P48T80 solution | solution of P48T80 DNA strand for usage with ENZ-80-1-R1-X or ENZ-80-1-Y1-X, P48T80 500 μL / 1 μM |
CNL-P80T80-500 | P80T80 solution | solution of P80T80 DNA strand for usage with ENZ-80-1-R1-X or ENZ-80-1-Y1-X, P80T80 500 μL / 1 μM |
CNL-QRF-B48-500 | cNL-B48-QRF solution | solution of complementary DNA lever for sequence B48 modified with a quenching molecule for the red fluorophore 500 μL / 1 μM |
CNL-QRF-B96-500 | cNL-B96-QRF solution | solution of complementary DNA lever for sequence B96 modified with a quenching molecule for the red fluorophore 500 μL / 1 μM |
CNL-QYF-B48-500 | cNL-B48-QYF solution | solution of complementary DNA lever for sequence B48 modified with a quenching molecule for the yellow fluorophore 500 μL / 1 μM |
CNL-QYF-B96-500 | cNL-B96-QYF solution | solution of complementary DNA lever for sequence B96 modified with a quenching molecule for the yellow fluorophore 500 μL / 1 μM |
CNL-QGF-B48-500 | cNL-B48-QGF solution | solution of complementary DNA lever for sequence B48 modified with a quenching molecule for the green fluorophore 500 μL / 1 μM |
CNL-QGF-B96-500 | cNL-B96-QGF solution | solution of complementary DNA lever for sequence B96 modified with a quenching molecule for the green fluorophore 500 μL / 1 μM |
CNL-QGF-A48-500 | QGF solution for green fluorophore | solution of complementary DNA lever for sequence A48 modified with a green fluorophore quencher molecule, cNL-A48-QGF 500 μL / 1 μM |
CNL-QGF-A96-500 | QGF solution for green fluorophore | solution of complementary DNA lever for sequence A96 modified with a green fluorophore quencher molecule, cNL-A96-QGF 500 μL / 1 μM |
CNL-Cas-A48-500 | cNL-Cas-A48 solution | solution of complementary DNA lever for sequence A48, without PAM-region cNL-Cas-A48 500 μL / 1 μM |
CNL-Cas-B48-500 | cNL-Cas-B48 solution | solution of complementary DNA lever for sequence B48, without PAM-region cNL-Cas-B48 500 μL / 1 μM |
SOL-PAS-1-5 | 10x Passivation solution | for passivation of chip surface (5 x 1 mL) |
SOL-REG-1-5 | Regeneration solution | for regeneration of chip surface (5 x 1mL) |
SOL-REG-5-1 | Regeneration solution | for regeneration of chip surface (5 x 1 mL) |
SOL-REG-UR-12-1 | Urea solution | 7 M urea (1 x 12 mL) |
Would you like to get more INFO
or arrange a DEMO?
Contact us, we will get in touch with you shortly!
Selection of Coupling Kits
This guide helps you towards the right approach for a successful switchSENSE®experiment.
Please follow the 2-step guide below to be directly transferred to the coupling kit, which is of interest for you.
Step 1 I Immobilization Methods
The biochip surface is functionalized with single-stranded DNA. The versatility of the experiment lies in ability to hybridize a wide-array of complementary DNA sequences. Your molecule of interest, referred to as the ligand, is immobilized onto the double-stranded DNA nanolever, either by direct covalent coupling or by tag-capturing methods.
switchSENSE® offers plenty of solutions for the immobilization of your ligand.
Please choose from the given options on the right.
_
Covalent Coupling
Tag Capture Methods
Step 2 I Covalent Coupling
We offer three different solutions using pre-established protocols for the covalent immobilisation of your biomolecules.
Amine Coupling, Thiol Coupling and Customized Strategies.
Most of them are known for a long time and are easy to use and work under physiological conditions with different kind of buffers and additives (please check in the respective user manual). The kits are optimized to ensure a 1:1 coupling between the nanolevers and ligands.
To ensure highest quality of your conjugate we offer two different purification methods:
1. Chromatographic method for highest performance
2. Spin columns protocol (faster)
Amine Coupling
Thiol Coupling
Customized Strategies
Covalent Coupling Kits
Amine Coupling
For Amine Coupling there are different kits available to address your needs.
You can order kits for the functionalization of 48mer, 96mer and bispecific nanolevers.
In switchSENSE® Amine Coupling Kits we solely use standard pre-established chemistry.
Amine Coupling Kit 1
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series.
CK-NH2-1-A48
CK-NH2-1-A96
CK-NH2-1-B48
CK-NH2-1-B96
Amine Coupling Kit 2
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series (spin column purification).
CK-NH2-2-B48
CK-NH2-2-B96
Amine Coupling Kit 3
For small molecules and peptides (<5 kDa); cNL-B48 or cNL-B96 and NHS modifier, sufficient for 5 conjugation series.
CK-NH2-3-B48
Amine Coupling Kit 4
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series.
CK-NH2-4-B48
Amine Coupling Kit 5
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series (spin column purification).
CK-NH2-5-B96
Amine Coupling Kit 6
For small molecules and peptides (<5 kDa); cNL-B48 or cNL-B96 and NHS modifier, sufficient for 5 conjugation series.
CK-NH2-6-B96
Amine Coupling Kit 7
Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube.
Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500).
CK-NH2-7-B48
CK-NH2-7-B96
Thiol Coupling
For Thiol Coupling there are different kits available to address your needs.
You can order kits for the coupling of a ligand to 48mer and 96mer nanolevers.
In switchSENSE® Thiol Coupling Kits we solely use standard maleimide chemistry.
Thiol Coupling Kit 1
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series.
CK-SH-1-B48
CK-SH-1-B96
Thiol Coupling Kit 2
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series (spin column purification).
CK-SH-2-B48
Thiol Coupling Kit 3
For small molecules and peptides (<5 kDa); cNL-B48 or cNL-B96 and NHS modifier, sufficient for 5 conjugation series.
CK-SH-3-B48
Customized Strategies
Both copper catalyzed and copper-free click chemistry are compatible with the switchSENSE® technology.
For further information on customized solutions, please send an email to support@dynamic-biosensors.com
Click Coupling Kit
For proteins (>5 kDa); cNL B48 or B96 and NHS modifier, sufficient for 5 conjugation series.
CK-CLK-1-B48
Step 2 I Tag Capture Methods
We offer a large array of options for the non-covalent immobilisation of your biomolecules using tag-capture.
Proteins are expressed with a variety of different tags, which can be targeted for binding to the DNA nanolevers. Complementary DNA conjugated with the second interaction component is hybridized onto the biosensor surface, and used for the capture of your molecule or interest.
Tris-NTA Kit
cNL-B48 and cNL-B96 modified with Tris-NTA, sufficient for 20 regenerations. Suitable for His-tagged proteins.
CK-TN-1-B48
CK-TN-1-B96
Streptavidin Kit
cNL-B48 and cNL-B96 modified with Streptavidin, sufficient for 10 regenerations. Very strong binder of biotinylated molecules.
CK-SA-1-B48
CK-SA-1-B96
FC A Kit
cNL-B48 and cNL-B96 modified with Protein A, sufficient for 10 regenerations. Can be used for capturing antibodies.
CK-FC-1-B48
CK-FC-1-B96
FC G Kit
cNL-B48 and cNL-B96 modified with Protein G, sufficient for 10 regenerations. Can be used for capturing antibodies.
CK-FC-2-B48
CK-FC-2-B96
GFP Binding Protein Kit
cNL-B48 and cNL-96 modified with GFP binding protein*, sufficient for 10 regenerations. Strong binder of GFP-fusion proteins.
CK-GFP-1-B48
CK-GFP-1-B96
GST Binding Protein Kit
cNL-B48 and cNL-B96 modified with GST binding protein*, sufficient for 20 regenerations. Strong binder of GST-fusion proteins.
CK-GST-1-B48
CK-GST-1-B96
Digoxigenin Kit
cNL-B48 and cNL-B96 modified with digoxigenin, sufficient for 20 regenerations.
CK-DG-1-B48
CK-DG-1-B96
Strep-Tactin® XT Kit
cNL-B96 modified with Strep-Tactin® XT, sufficient for 20 regenerations. Strong binder of protein modified with a Twin Strep-tag®.
CK-SXT-1-B96
Selected Kit
CK-NH2-1-A48
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence A48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
- Only use in combination with CK-NH2-1-B48 for double color application
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-1-A96
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Longer nanolever for larger complexes
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence A96
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-30 regenerations each; up to 200)
- Compatible with automated Standard regeneration process
- Only use in combination with CK-NH2-1-B96 for double color application
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-1-B48
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-1-B96
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Longer nanolever for larger complexes
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B96
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-30 regenerations each; up to 200)
- Compatible with automated Standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-2-B48
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - No chromatographic purification necessary
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-2-B96
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Longer nanolever for larger complexes
- No chromatographic purification necessary
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B96
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-30 regenerations each; up to 200)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-3-B48
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for peptides and small molecules (MW < 5 kDa)
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 200 regenerations each)
- Compatible with automated Standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-4-B48
Key Features
- In comparison with the Standard Amine Coupling Kit 1 this microKit requires only 20% of the starting quantity of protein
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 2-20 regenerations each)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-5-B96
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B96
- Two ligands – one nanolever
- Short distance between ligands: 7 nm
- Suitable for bifunctional molecules, e.g. bispecific antibodies
- Coupling of two ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate
- Includes reagents for 2 x 5 individual conjugation reactions (approx. 10-15 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-6-B96
Key Features
- Coupling of two biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B96
- Two ligands – one nanolever
- Long distance between ligands: 14 nm
- Suitable for bifunctional molecules, e.g. bispecific antibodies
- Coupling of two ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate
- Includes reagents for 2 x 5 individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SH-1-B48
Key Features
- Coupling of biomolecules with free thiols (e.g. cysteines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SH-1-B96
Key Features
- Coupling of biomolecules with free thiols (e.g. cysteines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Longer nanolevers for larger complexes
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B96
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-30 regenerations each; up to 200)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SH-2-B48
Key Features
- Coupling of biomolecules with free thiols (e.g. cysteines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for proteins (and peptides)
(MW > 5 kDa) - No chromatographic purification nesssary
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate
- Includes reagents for five individual conjugation reactions (approx. 10-30 regenerations each; up to 200)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SH-3-B48
Key Features
- Coupling of biomolecules with free thiols (e.g. cysteines) to modified nanolevers in a reaction tube
- Convenient standard chemistry
- Applicable for peptides and small molecules (MW > 5 kDa)
- Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate
- Includes reagents for five individual conjugation reactions (approx. 200 regenerations each)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-CLK-1-B48
Key Features
- cNL-B48 modified with Dibenzocyclooctyne (DBCO)
- Coupling of biomolecules with an azide to DBCO modified nanolevers in a reaction tube
- Bioorthogonal conjugation method
- Applicable for proteins (and peptides)
(MW > 5 kDa) - Compatible with all switchSENSE® multi-purpose biochips carrying sequence B48
- Suitable for parallel measurements via DNA encoded addressing
- Coupling of multiple ligands can be performed simultaneously
- Yields >95 % pure ligand – DNA conjugate with controlled quality of your product
- Includes reagents for five individual conjugation reactions (approx. 10-50 regenerations each; up to 500)
- Compatible with automated standard regeneration process
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-TN-1-B48
Key Features
- cNL-B48 modified with a Tris-NTA
- Used for capturing of His-tagged peptides and proteins (KD ~ 5 nM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for sizing and conformational change analysis
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 x 10 immobilizations of His-tagged peptides and proteins
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-TN-1-B96
Key Features
- cNL-B96 modified with a Tris-NTA
- Used for capturing of His-tagged peptides and proteins (KD ~ 5 nM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for conformational change analysis
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 x 10 immobilizations of His-tagged peptides and proteins
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SA-1-B48
Key Features
- cNL-B48 modified with Streptavidin
- This kit is intendend for use as an immobilization method for biotinylated ligands (KD ~ fM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for conformational change analysis
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of biotinylated ligands
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SA-1-B96
Key Features
- cNL-B96 modified with Streptavidin
- This Streptavidin-kit is intendend for use as an immobilization method for biotinylated ligands (KD ~ fM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for conformational change analysis
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of biotinylated ligands
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-SXT-1-B96
Key Features
- cNL-B96 modified with Strep-Tactin®XT
- This kit is intendend for use as an immobilization method for Twin-Strep-tag® proteins (KD ~ pM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for conformational change analysis
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of ligands modified with a Twin-Strep-tag®
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
Strep-Tactin® XT is a product of IBA GmbH
CK-FC-1-B48
Key Features
- cNL-B48 modified with Protein A
- This kit is intendend for use as a capture method for various IgG species (KD ~ nM, depending on IgG species)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of an IgG
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-FC-1-B96
Key Features
- cNL-B96 modified with Protein A
- This kit is intendend for use as a capture method for various IgG species (KD ~ nM, depending on IgG species)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of an IgG
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-FC-2-B48
Key Features
- cNL-B48 modified with Protein G
- This kit is intendend for use as a capture method for various IgG species (KD ~ nM, depending on IgG species)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of an IgG
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-FC-2-B96
Key Features
- cNL-B96 modified with Protein G
- This kit is intendend for use as a capture method for various IgG species (KD ~ nM, depending on IgG species)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of an IgG
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-GFP-1-B48
Key Features
- cNL-B48 modified with a GFP binding protein
- This kit is intendend for use as a capture method for GFP-fusion proteins (KD ~ pM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a GFP-fusion protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
GFP / GST binding protein is a product of ChromoTek GmbH
CK-GFP-1-B96
Key Features
- cNL-B96 modified with a GFP binding protein
- This kit is intendend for use as a capture method for GFP-fusion proteins (KD ~ pM)
- This kit is intendend for use as a capture method for various IgG species with nM affinity
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a GFP-fusion protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
GFP / GST binding protein is a product of ChromoTek GmbH
CK-GST-1-B48
Key Features
- cNL-B48 modified with a GST binding protein
- This kit is intendend for use as a capture method for GST-fusion proteins (KD ~ pM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a GST-fusion protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
GFP / GST binding protein is a product of ChromoTek GmbH
CK-GST-1-B96
Key Features
- cNL-B96 modified with a GST binding protein
- This kit is intendend for use as a capture method for GST-fusion proteins (KD ~ pM)
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a GST-fusion protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
GFP / GST binding protein is a product of ChromoTek GmbH
CK-BI-1-B48
Key Features
- cNL-B48 modified with Biotin
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of Streptavidin
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-BI-1-B96
Key Features
- cNL-B96 modified with Biotin
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of Streptavidin
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-DG-1-B48
Key Features
- cNL-B48 modified with Digoxigenin
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B48
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a Digoxigenin binding protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-DG-1-B96
Key Features
- cNL-B96 modified with Digoxigenin
- Compatible with all switchSENSE® Multi-purpose biochips carrying sequence B96
- Suitable for kinetic and titration measurements
- Suitable for parallel measurements via DNA encoded addressing
- Includes reagents for 20 immobilizations of a Digoxigenin binding protein
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-7-B48
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Suitable for parallel measurements via DNA encoded addressing
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.
CK-NH2-7-B96
Key Features
- Coupling of biomolecules with primary amines (e.g. NH2-terminus, lysines) to modified nanolevers in a reaction tube
- Suitable for parallel measurements via DNA encoded addressing
Find out what biochips this kit is compatible with.
DOWNLOAD our coupling kit / biochips compatibility matrix.